The Need for Non-conductive Matting is Critical If…
Team members are exposed to high-voltage electricity in the workplace
The work area has high-voltage warning signs to indicate electrical danger
Workplace safety and ensuring the safety of personnel is a priority
Diamond-Plate Switchboard Matting - Black with Yellow Borders
SKU | Short Description | Color | Thickness | Dimensions | Stock Part | UOM |
---|---|---|---|---|---|---|
701.14x3x5BYL | Diamond-Plate Switchboard Matting | Black w/Yellow | 1/4" | 3' x 5' | Yes | EA |
701.14x3x75BYL | Diamond-Plate Switchboard Matting | Black w/Yellow | 1/4" | 3' x 75' | Yes | RL |
Parameters of Category: Specifications - General
Suitable Environment | Dry |
Type | Non-Conductive |
Customization Level | C1 - Custom Length |
Solid or Drainage | Solid |
Compound | PVC |
Recycled | <10% |
Warranty | 1 Year |
Test Specification & Results
Property | Test / Result |
---|---|
Flammability | ASTM D178-01 / Maximum 12.7 mm after 30sec. |
Taber Abrasion | Not Available |
Temperature Range | Not Available |
Coefficient of Friction | Not Available |
Compression Deflection | Not Available |
Tear Strength | ASTM D412-98a Die C results: 1212 psi |
ESD Rating | Not Applicable |
Dielectric Strength | Surface conforms to ANSI/ASTM D178 01, Type II, Class 2: 30,000 volts. (Recommended Max Usage up to 17,000 volts) |
Key
- A = Performs well
- B = Slightly affected
- C = Moderately affected
- D = Highly affected
- U = Not recommended
- NT = Not tested
Chemical | Urethane | Nitrile | PVC | CFR | SBR | Natural Rubber |
---|---|---|---|---|---|---|
Acetone | U | U | U | C | C | C |
Animal Fats | NT | A | C | U | U | U |
Bleach Solution (10% Dilute) | NT | B | B | C | C | C |
Boric Acid | B | A | A | A | A | A |
Brake Fluid | U | A | B | D | D | D |
Brake Fluid (Silicone Based) | U | A | B | A | B | B |
Chlorine Solution (3% Dilute) | C | A | B | C | C | C |
Citric Acid | NT | A | C | C | C | U |
Cutting Fluid (Mineral Oil Based) | U | B | B | B | C | D |
Diesel Oil | U | A | B | U | U | U |
Ethylene Acetate | NT | U | NT | U | U | U |
Ethylene Glycol | B | A | A | A | A | A |
Hydraulic Oil (Petroleum) | U | A | B | D | D | D |
Hydrochloric Acid Cole (37% Dilute) | U | C | C | B | B | B |
Isopropyl Alcohol | A | B | A | B | B | A |
Lacquer Solvents | U | U | U | U | U | U |
Lindol (Hydraulic Fluid) | NT | U | NT | U | U | U |
MEK | U | U | U | U | U | U |
Mineral Oil | C | A | B | A | B | U |
Naptha | NT | C | U | U | U | U |
Napthlene | U | U | U | U | U | U |
Petroleum | U | C | B | D | D | D |
Salt Water | A | A | B | B | B | C |
Tolulene | U | U | U | U | U | U |
Transmission Fluid (Type A) | U | B | A | C | U | U |
Trichloroethane | U | U | U | U | U | U |
Vegetable Oil | C | A | B | C | C | C |
Q: What is Switchboard matting?
A: Also referred to as non-conductive matting, these products serve as an insulative barrier to protect personnel from dangerous and deadly shock. It's commonly used around high voltage areas, fuse boxes, switchgear, control panels and heavy machinery.
Q: How is the electrical insulation value of the matting rated?
A: In accordance with ASTM D149-97a testing standards, this mat meets the requirement of a minimum of 30,000 volts and recommended max usage of up to 17,000 volts.
Q: How often should switchboard matting be replaced?
A: All switchboard matting should be inspected and/or replaced every year to ensure the safety of personnel.
Q: Are the colors shown on your website the exact color I should expect to receive?
A: No, because monitors vary so there may be a slight variance in the color. If color choice is critical, we suggest that you order a sample. Due to manufacturing processes and material dye lots, color can vary, but our products fall within an industry-standard acceptable variation.