Checkout using your account
Checkout as a new customer
Creating an account has many benefits:
In stock
In stock
The sample was successfully added to your cart.
SKU | Short Description | Color | Thickness | Dimensions | Stock Part | UOM |
---|---|---|---|---|---|---|
791.12x2x3GY | Static Dissipative Anti-Fatigue | Gray | 1/2" | 2' x 3' | Yes | EA |
791.12x3x5GY | Static Dissipative Anti-Fatigue | Gray | 1/2" | 3' x 5' | Yes | EA |
791.12x3x75GY | Static Dissipative Anti-Fatigue | Gray | 1/2" | 3' x 75' | No | RL |
SKU | Short Description | Color | Thickness | Dimensions | Stock Part | UOM |
---|---|---|---|---|---|---|
Other | ||||||
793.HG | Made for workers wearing insulative shoes, the Heel Grounder allows static electricity to pass from the worker to the ESD matting or flooring. | Black | N/A | Yes | EA | |
793.15Cord | The 15' (4.6m) - long ESD Ground Cord is used to connect ESD tabletop and floor mats to ground. The molded-in fastener has an integral one-mega-ohm resistor, conforms to 10mm snaps, and features a solderless terminal. Can be used with all conductive mats. | Black | 15' | Yes | EA |
Product Family | Thickness | Width | Length | Color | Product Number | ||||
ML414 | . | 1516 | x | 2 | x | 10 | BK | = | ML414.1516x2x10BK |
Environment | Dry |
Wearwell Categories | Anti-Fatigue Matting |
Customization Level | C1 - Custom Length |
Solid or Drainage | Solid |
Compound | PVC Surface With Nitrile Infused Sponge |
Recycled | <10% |
Warranty | 1 Year |
WARNING | WARNING: This product can expose you to chemicals including Di(2-ethylhexyl) phthalate, which is known to the State of California to cause cancer and reproductive harm. For more information, go to www.P65Warnings.ca.gov. |
Property | Test / Result |
---|---|
Flammability | MVSS 302 / 'A'; Rating |
Taber Abrasion | Federal Standard 191 |
Temperature Range | 0 to 110 F |
Coefficient of Friction | ASTM F1677 / Dry: COF = .62 / Wet: COF = .17 |
Compression Deflection | Not Available |
Tear Strength | Not Available |
ESD Rating | EOS/ESD S7.1: 1x10^6-1x10^9 (meets ANSI/ESD 20.20 requirements) |
Dielectric Strength | Not Available |
Key
Chemical | Urethane | Nitrile | PVC | CFR | SBR | Natural Rubber |
---|---|---|---|---|---|---|
Acetone | U | U | U | C | C | C |
Animal Fats | NT | A | C | U | U | U |
Bleach Solution (10% Dilute) | NT | B | B | C | C | C |
Boric Acid | B | A | A | A | A | A |
Brake Fluid | U | A | B | D | D | D |
Brake Fluid (Silicone Based) | U | A | B | A | B | B |
Chlorine Solution (3% Dilute) | C | A | B | C | C | C |
Citric Acid | NT | A | C | C | C | U |
Cutting Fluid (Mineral Oil Based) | U | B | B | B | C | D |
Diesel Oil | U | A | B | U | U | U |
Ethylene Acetate | NT | U | NT | U | U | U |
Ethylene Glycol | B | A | A | A | A | A |
Hydraulic Oil (Petroleum) | U | A | B | D | D | D |
Hydrochloric Acid Cole (37% Dilute) | U | C | C | B | B | B |
Isopropyl Alcohol | A | B | A | B | B | A |
Lacquer Solvents | U | U | U | U | U | U |
Lindol (Hydraulic Fluid) | NT | U | NT | U | U | U |
MEK | U | U | U | U | U | U |
Mineral Oil | C | A | B | A | B | U |
Naptha | NT | C | U | U | U | U |
Napthlene | U | U | U | U | U | U |
Petroleum | U | C | B | D | D | D |
Salt Water | A | A | B | B | B | C |
Tolulene | U | U | U | U | U | U |
Transmission Fluid (Type A) | U | B | A | C | U | U |
Trichloroethane | U | U | U | U | U | U |
Vegetable Oil | C | A | B | C | C | C |
A: These products have been tested by the National Floor Safety Institute per the NFSI 101-C Test Method and have passed the NFSI “High-Traction” standard.
A: From a technical point of view, the answer is to confirm the OHM rating required by your application, then choose the product that meets your required OHM rating. Conductive products have a lower OHM rating. That means that there is less resistance and therefore, conductive products will allow static electricity to ground out faster than a static dissipative product, which has a higher OHM rating, and therefore higher resistance.
A: An OHM is a unit of measure that defines electrical resistance between two points. The lower the OHM reading the lower the resistance to electricity passing through and therefore the faster electricity can pass through to ground. There is a specific range of OHM ratings that define the difference between a conductive product and a static dissipative product. Choose the product which has an OHM rating that meets the requirements of your application.
A: ESD (Electrostatic discharge) is the sudden flow of electricity between two electrically charged objects caused by contact. ESD is the cause for that annoying "zap" you get when you reach for a metal door handle. Your body and clothing accumulate static electricity. That static electricity desperately wants to reach a ground point. ESD matting and flooring is intended to prevent unintentional discharges of static electricity by creating a path to ground through your body and out through the mat or floor for static electricity that is accumulated in your body and clothing.
A: To allow the flow of electricity to reach a ground source, a heel strap must be worn if the operator is wearing non-conductive soled shoes.
A: No, because monitors vary so there may be a slight variance in the color. If color choice is critical, we suggest that you order a sample. Due to manufacturing processes and material dye lots, color can vary, but our products fall within an industry-standard acceptable variation.