Parameters of Category: Specifications - General
Suitable Environment Dry
Type Anti-Fatigue Matting
Customization Level C3 - Full Custom (Length, Width, Shape)
Solid or Drainage Solid
Compound Grease Resistant Natural Rubber
Recycled <10%
Warranty 1 Year
Putting Together Wearwell Part Numbers

See an example of how Wearwell puts together their part numbers.


Part Number Description Color Thickness Dimensions Stock Part UOM
788.12x3x3GRBK Modular Diamond-Plate ESD Black 1/2" 3' x 3' Yes EA

Ramps and accessories

Part Number Description Color Thickness Dimensions Stock Part UOM
Other
793.15Cord 15' Cord Black 15' Yes EA
793.HG Heel Grounder Black N/A Yes EA
Test Specification & Results
Property Test / Result
Flammability MVSS 302 / 'A'; Rating
Taber Abrasion Not Available
Temperature Range -50 to 250 F
Coefficient of Friction ASTM F1677 / Dry: COF = >.84 / Wet: COF = .78 / Oily: COF = .34
Compression Deflection ASTM D575 / Deflection @35 psi, mm = 4.10
Tear Strength Not Available
ESD Rating EOS/ESD S7.1: RTT= 1 x 10^6 to 1 x 10^10
Dielectric Strength Not Available

Key

  • A = Performs well
  •  B = Slightly affected
  •  C = Moderately affected
  • D = Highly affected
  •  U = Not recommended
  •  NT = Not tested
ChemicalUrethaneNitrilePVCCFRSBRNatural Rubber
Acetone U U U C C C
Animal Fats NT A C U U U
Bleach Solution (10% Dilute) NT B B C C C
Boric Acid B A A A A A
Brake Fluid U A B D D D
Brake Fluid (Silicone Based) U A B A B B
Chlorine Solution (3% Dilute) C A B C C C
Citric Acid NT A C C C U
Cutting Fluid (Mineral Oil Based) U B B B C D
Diesel Oil U A B U U U
Ethylene Acetate NT U NT U U U
Ethylene Glycol B A A A A A
Hydraulic Oil (Petroleum) U A B D D D
Hydrochloric Acid Cole (37% Dilute) U C C B B B
Isopropyl Alcohol A B A B B A
Lacquer Solvents U U U U U U
Lindol (Hydraulic Fluid) NT U NT U U U
MEK U U U U U U
Mineral Oil C A B A B U
Naptha NT C U U U U
Napthlene U U U U U U
Petroleum U C B D D D
Salt Water A A B B B C
Tolulene U U U U U U
Transmission Fluid (Type A) U B A C U U
Trichloroethane U U U U U U
Vegetable Oil C A B C C C

Write a Review

You're reviewing: Modular Diamond-Plate ESD

How do you rate this product?*

*Required Field


Customer Reviews

1 Review

Solves two problems for me
This is a nice, heavy mat that both provides ESD protection and acts as a wear surface for my lab chair, one that can be replaced over time, if necessary. However, the mat is quite thick, and I think it will be many years before I need to replace it! (Posted on 5/29/2015)

Q: Do I need conductive or Static Dissipative flooring?

A: From a technical point of view, the answer is to confirm the OHM rating required by your application, then choose the product that meets your required OHM rating. Conductive products have a lower OHM rating. That means that there is less resistance and therefore, conductive products will allow static electricity to ground out faster than a static dissipative product, which has a higher OHM rating, and therefore higher resistance.


Q: What does the OHM rating tell me?

A: An OHM is a unit of measure that defines electrical resistance between two points.The lower the OHM reading the lower the resistance to electricity passing through and therefore the faster electricity can pass through to ground.There is a specific range of OHM ratings that define the difference between a conductive product and a static dissipative product. Choose the product which has an OHM rating that meets the requirements of your application.


Q: What is ESD?

A: ESD (Electrostatic discharge) is the sudden flow of electricity between two electrically charged objects caused by contact. ESD is the cause for that annoying "zap" you get when you reach for a metal door handle. Your body and clothing accumulate static electricity. That static electricity desperately wants to reach a ground point. ESD matting and flooring is intended to prevent unintentional discharges of static electricity by creating a path to ground through your body and out through the mat or floor for static electricity that is accumulated in your body and clothing.


Q: Do I still need heel grounding straps?

A: To allow the flow of electricity to reach a ground source, a heel strap must be worn if the operator is wearing non-conductive soled shoes.


Q: Are the colors shown on your website the exact color I should expect to receive?

A: No, because monitors vary so there may be a slight variance in the color. If color choice is critical, we suggest that you order a sample. Due to manufacturing processes and material dye lots, color can vary, but our products fall within an industry-standard acceptable variation.