Electrically Conductive, Diamond-Plate

Electrically Conductive Runner is the ideal floor runner for areas where static prevention is a priority. Can be rolled out for long aisle ways or cut to size for specific workstations. Use Electrically Conductive Runner to protect sensitive equipment or eliminate static annoyance. A grounding snap is included on each mat, and grounding is highly recommended for optimum mat performance. Also recommended: workers should wear heel grounders or shoes with conductive soles for max effectiveness.

  • Treated surface drains static electricity from personnel
  • Available in Smooth or Diamond-Plate surface pattern
  • Overall thickness, Smooth 3/32” or Diamond-Plate 5/32”
  • Grounding snap is attached to the corner of each mat (NOTE: Mat must be grounded with a ground cord; workers must wear Heel Grounder or shoes with conductive soles)
  • Need a different size? 1’ incremental lengths are available! Simply give us a shout out!

Learn more about ESD flooring and matting in our blog - ESD 101: Everything You Need to Know About ESD Mats, Flooring, and Work Surfaces.

+ Read More
Have a question? We're here to help!
Putting Together Wearwell Part Numbers
See an example of how Wearwell puts together their part numbers.

SKU Short Description Colour Thickness Dimensions Stock Part UOM
785.532x3x10DPBK Electrically Conductive Runner Diamond-Plate Black 5/32" Yes EA
785.532x3x5DPBK Electrically Conductive Runner Diamond-Plate Black 5/32" Yes EA
785.532x3x75DPBK Electrically Conductive, Diamond-Plate Black 5/32" 91 cm x 2286 cm Yes RL
785.532X4X75DPBK Electrically Conductive Runner,Diamond-Plate w/Snap Black,5/32in x 4ft x 75ft Full Roll Black 5/32" No EA

Ramps and accessories

SKU Short Description Colour Thickness Dimensions Stock Part UOM
Other
793.HG Heel Grounder Black N/A Yes EA
793.15Cord 15' Cord Black 457 Yes EA
Parameters of Category: Specifications - General
Suitable EnvironmentDry
Wearwell CategoriesRunner
Customisation LevelC1 - Custom Length
Solid or DrainageSolid
CompoundPVC
Recycled<10%
Warranty1 Year
Test Specification & Results
PropertyTest / Result
Flammability MVSS 302 / 'A'; Rating
Taber Abrasion Federal Standard 191
Temperature Range Not Available
Coefficient of Friction ASTM F1677 / Dry: COF = .68 / Wet: COF = .17
Compression Deflection Not Available
Tear Strength Not Available
ESD Rating EOS/ESD S7.1: 1,000 Ω – 1,000,000 Ω ohms
Dielectric Strength Not Available

Key

  • A = Performs well
  • B = Slightly affected
  • C = Moderately affected
  • D = Highly affected
  • U = Not recommended
  • NT = Not tested
Chemical Urethane Nitrile PVC CFR SBR Natural Rubber
Acetone U U U C C C
Animal Fats NT A C U U U
Bleach Solution (10% Dilute) NT B B C C C
Boric Acid B A A A A A
Brake Fluid U A B D D D
Brake Fluid (Silicone Based) U A B A B B
Chlorine Solution (3% Dilute) C A B C C C
Citric Acid NT A C C C U
Cutting Fluid (Mineral Oil Based) U B B B C D
Diesel Oil U A B U U U
Ethylene Acetate NT U NT U U U
Ethylene Glycol B A A A A A
Hydraulic Oil (Petroleum) U A B D D D
Hydrochloric Acid Cole (37% Dilute) U C C B B B
Isopropyl Alcohol A B A B B A
Lacquer Solvents U U U U U U
Lindol (Hydraulic Fluid) NT U NT U U U
MEK U U U U U U
Mineral Oil C A B A B U
Naptha NT C U U U U
Napthlene U U U U U U
Petroleum U C B D D D
Salt Water A A B B B C
Tolulene U U U U U U
Transmission Fluid (Type A) U B A C U U
Trichloroethane U U U U U U
Vegetable Oil C A B C C C
Write Your Own Review
You're reviewing:Electrically Conductive, Diamond-Plate
Your Rating

Q: Do I need conductive or Static Dissipative flooring?

A: From a technical point of view, the answer is to confirm the OHM rating required by your application, then choose the product that meets your required OHM rating. Conductive products have a lower OHM rating. That means that there is less resistance and therefore, conductive products will allow static electricity to ground out faster than a static dissipative product, which has a higher OHM rating, and therefore higher resistance.


Q: What does the OHM rating tell me?

A: An OHM is a unit of measure that defines electrical resistance between two points. The lower the OHM reading the lower the resistance to electricity passing through and therefore the faster electricity can pass through to ground. There is a specific range of OHM ratings that define the difference between a conductive product and a static dissipative product. Choose the product which has an OHM rating that meets the requirements of your application.


Q: What is ESD?

A: ESD (Electrostatic discharge) is the sudden flow of electricity between two electrically charged objects caused by contact. ESD is the cause for that annoying "zap" you get when you reach for a metal door handle. Your body and clothing accumulate static electricity. That static electricity desperately wants to reach a ground point. ESD matting and flooring is intended to prevent unintentional discharges of static electricity by creating a path to ground through your body and out through the mat or floor for static electricity that is accumulated in your body and clothing.


Q: Do I still need heel grounding straps?

A: To allow the flow of electricity to reach a ground source, a heel strap must be worn if the operator is wearing non-conductive soled shoes.


Q: Are the colors shown on your website the exact color I should expect to receive?

A: No, because monitors vary so there may be a slight variance in the color. If color choice is critical, we suggest that you order a sample. Due to manufacturing processes and material dye lots, color can vary, but our products fall within an industry-standard acceptable variation.